Spectrometers and Accessories
The
USB4000 spectrometers are miniature fiber optic UV-VIS-NIR detection
systems for low light level applications. They are compact and portable,
measuring just 63.34 mm x 89.10 mm x 34.37 mm, and weighing only 180 g. These
spectrometers accept light energy transmitted through single-strand optical
fiber and disperses it via a fixed grating across the CCD array. These
spectrometers are compatible with all of our FIA/SIA systems.
FIAlab offers three configurations as listed below. Custom
and Multiple channel configurations are also available, please inquire. For
accessories such as light sources, and optical cables,
visit our spectrometer accessories page.
These spectrometers are plug and play
compatible with
FIAlab for Windows software, which is included with
the purchase of a complete FIAlab system. The spectrometers can also be
controlled by Spectrasuite
software, purchased separately.
Technical Specifications:
USB4000
UV-VIS for Colorimetric assays between 200 and 850 nm.
|
The
USB4000-UV-VIS Spectrometer is pre-set to a 200-850 nm wavelength
range and comes with a UV2 Detector Upgrade, a multi-bandpass order-sorting
detector coating and a 25
mm
entrance slit for optical resolution to 1.5 nm (FWHM). Operating software is
included.
|
Detector: |
3648-element
Toshiba TCD1304AP Linear CCD array |
|
Useable range: |
200-850 nm
(grating-dependent) |
|
Dynamic range: |
2 x 108 |
|
Sensitivity
(estimate): |
|
|
Signal-to-Noise: |
300:1 (at full
signal) |
|
Dark noise: |
12 RMS counts |
|
Grating: |
600 lines/mm, set
to 200-850 nm (blazed at 300 nm) |
|
Slit: |
25
mm
width (height is 1000 mm) |
|
Focal length: |
42 mm (input); 68 mm (output) |
|
Order-sorting: |
Single-piece, multi-bandpass
detector coating to eliminate second-order effects from 200-850 nm |
|
Resolution: |
1.5 nm (FWHM) |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm
< 0.10% at 250 nm |
|
Price |
$3,061.00 |
|
|
The
USB4000-VIS-NIR Spectrometer is pre-set to a 350-1000 nm wavelength
range and comes with a multi-bandpass order-sorting detector coating and a
25 mm
entrance slit for optical resolution to 1.5 nm (FWHM). Operating software is
included. |
|
Detector: |
3648-element
Toshiba TCD1304AP Linear CCD array |
|
Useable range: |
350-1000 nm
|
|
Dynamic range: |
2 x 108 |
|
Sensitivity
(estimate): |
|
|
Signal-to-Noise: |
300:1 (at full
signal) |
|
Dark noise: |
12 RMS counts |
|
Grating: |
600 lines/mm, set
to 350-1000 nm (blazed at 500 nm) |
|
Slit: |
25
mm
width (height is 1000 mm) |
|
Focal length: |
42 mm (input); 68
mm (output) |
|
Order-sorting: |
Single-piece,
multi-bandpass detector coating to eliminate second-order effects from
350-1000 nm |
|
Resolution: |
1.5 nm (FWHM) |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm |
|
Price |
$2,887.00 |
|
|
The
USB4000-VIS-NIR-FL Spectrometer is
pre-set to a 350-1000 nm wavelength range and is built with a large 200
micron slit and L4 colection lense, making it ideal for fluorometric
assays. It is also an excellent detector for colorimetric work. |
|
Detector: |
3648-element
Toshiba TCD1304AP Linear CCD array |
|
Useable range: |
350-1000 nm
|
|
Sensitivity
(estimate): |
|
|
Signal-to-Noise: |
300:1
(at full signal) |
|
Dark noise: |
50
RMS counts |
|
Grating: |
Grating #3 -- groove density 600 lines
per millimeter, 360-1000 nm, 500 nm blaze |
|
Slit: |
200
mm
width (height is 1000 mm) |
|
Detector
collection |
L4 |
|
Price |
$2,887.00 |
|
|
|
Please email or phone FIAlab Instruments
for additional product information.