FIAlab Instruments, Inc.
14450 NE 29th Place STE 113
Bellevue, WA 98007 USA
Voice: 425-376-0450
Fax: 425-376-0451
fialab@flowinjection.com
|
|
Spectrometers and Accessories
|

|
The USB2000/USB4000 spectrometers are miniature
fiber optic UV-VIS-NIR detection systems for low light level applications.
They are compact and portable, measuring just
63.34 mm x 89.10 mm x 34.37 mm, and
weighing only 180 g.
These spectrometers accept
light energy transmitted through single-strand optical fiber and disperses it
via a fixed grating across the CCD array. These spectrometers are
compatible with all of our FIA/SIA systems.
FIAlab offers three
configurations as listed below. Custom
and Multiple channel configurations are also
available, please inquire.
For accessories
such as flowcells, light sources, and optical cables,
visit our spectrometer accessories page.
Please contact FIAlab to
purchase these spectrometers, or
.
|
Technical Specifications:
USB4000
UV-VIS for Colorimetric assays between 200 and 850 nm.
|
The
USB4000-UV-VIS Spectrometer is pre-set to a 200-850 nm wavelength
range and comes with a UV2 Detector Upgrade, a multi-bandpass order-sorting
detector coating and a 25
mm
entrance slit for optical resolution to 1.5 nm (FWHM). Operating software is
included.
|
Detector: |
3648-element
Toshiba TCD1304AP Linear CCD array |
|
Useable range: |
200-850 nm
(grating-dependent) |
|
Dynamic range: |
2 x 108 |
|
Sensitivity
(estimate): |
|
|
Signal-to-Noise: |
300:1 (at full
signal) |
|
Dark noise: |
12 RMS counts |
|
Grating: |
600 lines/mm, set
to 200-850 nm (blazed at 300 nm) |
|
Slit: |
25
mm
width (height is 1000 mm) |
|
Focal length: |
42 mm (input); 68 mm (output) |
|
Order-sorting: |
Single-piece, multi-bandpass
detector coating to eliminate second-order effects from 200-850 nm |
|
Resolution: |
1.5 nm (FWHM) |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm
< 0.10% at 250 nm |
|
Price |
$2,782.00 |
|
USB4000
VIS-NIR for Colorimetric assays between 350 and 1000 nm.
|
The
USB4000-VIS-NIR Spectrometer is pre-set to a 350-1000 nm wavelength
range and comes with a multi-bandpass order-sorting detector coating and a
25 mm
entrance slit for optical resolution to 1.5 nm (FWHM). Operating software is
included. |
|
Detector: |
3648-element
Toshiba TCD1304AP Linear CCD array |
|
Useable range: |
350-1000 nm
(grating-dependent) |
|
Dynamic range: |
2 x 108 |
|
Sensitivity
(estimate): |
|
|
Signal-to-Noise: |
300:1 (at full
signal) |
|
Dark noise: |
12 RMS counts |
|
Grating: |
600 lines/mm, set
to 350-1000 nm (blazed at 500 nm) |
|
Slit: |
25
mm
width (height is 1000 mm) |
|
Focal length: |
42 mm (input); 68
mm (output) |
|
Order-sorting: |
Single-piece,
multi-bandpass detector coating to eliminate second-order effects from
350-1000 nm |
|
Resolution: |
1.5 nm (FWHM) |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm |
|
Price |
$2,624.00 |
|
USB2000
VIS-NIR-FL for Fluorometric assays between 350 and 1000 nm
|
The
USB2000-VIS-NIR-FL Spectrometer is
pre-set to a 350-1000 nm wavelength range and is built with a large 200
micron slit and L4 colection lense, making it ideal for fluorometric
assays. It is also an excellent detector for colorimetric work. |
|
Detector: |
2048 pixels - Sony ILX511
linear silicon CCD array |
|
Useable range: |
360-1000 nm
(grating-dependent) |
|
Sensitivity
(estimate): |
-
400 nm: 75
photons/count
-
600 nm: 41
photons/count
|
|
Signal-to-Noise: |
250:1
(at full signal) |
|
Dark noise: |
3.2 RMS counts |
|
Grating: |
Grating #3 --
groove density 600 lines per millimeter, 360-1000 nm, 500 nm blaze |
|
Slit: |
200
mm
width (height is 1000 mm) |
|
Detector
collection |
L4 |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm |
|
Stray light: |
< 0.05% at 600 nm
< 0.10% at 435 nm |
|
Price |
$2,350.00 |
|
|
|
Please email or phone FIAlab Instruments
for additional product information.
Email:
fialab@flowinjection.com,
Voice: 425-376-0450 or 1-800-963-1101,
Fax: 425-376-0451
|
|