Solid Phase Extraction by FIA

 
Solid Phase Extraction Automated by FIA is a technique designed for rapid, selective sample preparation and purification prior to assay of target analytes by ICP-MS, Atomic Absorption, UV-VIS Spectrophotometry, Fluorescence or Chromatography.

Solid Phase Extraction  chemistries are available for Oceanographic, Pharmaceutical, Food and Beverage  Environmental, Petrochemical and Agricultural assays. The sample prep objectives include matrix removal and analyte accumulation. Typically a large sample volume is passed through the column filled with an appropriate stationary phase, on which target  analytes  are  selectively accumulated, while matrix components, that would interfere with the following quantitative assay,  are  washed away, please see link.

 

While majority of SPE based sample prep is carried out manually, the large number of samples to be processed justifies automation of the four basic steps of SPE protocol: 1/ column equilibration with a suitable solvent, 2/ sample injection and   target analyte  accumulation on  the sorbent while the solvent, salts, and other impurities pass through the column. 3/   washing of the column  with buffer, or by solvent to remove further impurities, 4/  elution of the analyte with a suitable  solvent, or by a buffer of an appropriate pH .

SPE-FIAlab2600 has been designed to automate these steps in a novel way, using state of art “lab-on-valve “ (LOV) manifold, specifically constructed  to accommodate SPE technique. After the column has been equilibrated (Eluent #2), the sample solution is mixed with a carrier stream containing buffer or a suitable  reagent,   designed to optimize conditions for capture of target analyte  on the stationary phase. During this step the non retained matrix is directed to waste.  When the wash is completed, the target analyte is released from the column ( Eluent #1) white the auxiliary pump directs the stream into a detector. The unique design of LOV manifold reduces dead volumes and saves reagents,  that are re circulated when not needed.


Sample injection and   target analyte accumulation on  the sorbent while the solvent, salts, and other impurities pass through the column.




Elution of the analyte with a suitable  solvent, or by a buffer of an appropriate pH .

SPE-FIAlab 2600 can be used asstand alone” instrument with manual operation at the front and rear end, or “sandwiched” between sample changer and fraction collector. However, FIAlab software allows the instrument to be coupled directly as a front end to Atomic Absorption or ICP-MS or any other detector suitable for quantization of   target analytes.

 

Pre packed columns, that can be attached directly to the LOV manifold  of SPE-FIA 2600 instrument are commercially available offering a wide variety of  stationary phases, including Sigma-Aldrich and Varian. 

The SPE-FIAlab-2600 includes an eight channel peristaltic pump, and SPE-LOV manifold.   This is similar in some respect to the form of the FIAlab-2600 standard system,  except with the SPE-LOV instead of the FIA-LOV.

Please contact FIAlab for technical discussions and a quotation for the SPE-FIAlab-2600.


Please email or phone FIAlab Instruments for additional product information.