PMT-FL Flow Thru Fluorometer
For Low Level Fluorescence
and Chemiluminescence Assays
|
PMT-FL shown with optional S2-Mini peristaltic pump
PMT-FL with sensor drawer slid open
PMT-FL connected with MicroSIA System
·
Photon
counting PMT detector · Dimensions: ~5 X 7 X 10 in (~13 X 18 X 25.4 cm) · 310nm - 750nm spectral range ·
Pulse
pair resolution: 10ns · Responsivity @ 400nm: 5 X 1017 cps/Watt ·
PMT
dynamic range: 2.0E06 ·
10 - 100
microliter
flow through cuvette ·
RS232
Control · Includes FIAlab for Windows operating software · Can be interfaced through Visual Basic, VC++, Labview, HPVEE, and other environments · Filters: each PMT-FL order includes your waveband choice of both excitation and emission filters (please enquire).
L9009: Luciferase Photinus pyralis. The bioluminescent reaction of this enzyme with luciferin, ATP, and O2 results in the emission of light. Luciferase can be used to detect trace amounts of ATP.
GUS-A: b-Glucuronidase Fluorescent Activity Detection Kit. The substrate used in this kit is MU-GlcA (4-methylumbelliferyl b-D-glucuronide), a widely used fluorogenic substrate for determination of glucuronidase activity. |
The PMT-FL
is a highly sensitive photomultiplier based flow through detection system ideally suited for ultra low fluorescence,
chemiluminescence or bioluminescence measurements. Parts per trillion sensitivity. Heavy-duty chemical resistant housing built to withstand
industrial environments. The
PMT-FL is built to order with either an internal excitation lamp or an SMA
terminated fiber optic cable for use with an external lamp (see configuration
options listed below). Emission and excitation filters are
mounted in user accessible slots inside the enclosure, allowing for quick
removal for exchange. The PMT-FL plugs into the RS-232 serial port of a personal computer. Included with the system is Windows based software, allowing the user to set the integration time and voltage counts, and to obtain time histories of the measurements, both plotted and tabulated. The software can also automatically create calibration curves, as well as controlling a host of additional devices such as FIAlab's FIA/SIA systems, syringe and peristaltic pumps, injection valves, selection valves, and autosamplers (please inquire for details). For users who desire to control the PMT-FL from their own software project, included is an ActiveX control for use with Visual Basic, VC++, Labview, or nearly any other ActiveX compatible development environment.
Optional internal excitation sources include: Laser Diodes (532 nm, 635 nm, 650 nm) Quartz tungsten lamp (440 - 750 nm) Mercury Vapor lamps (350 - 400 nm) UV LED lamp (270 - 410 nm) Various visible LED lamps
Optional fiber optic excitation sources include: All above + Deuterium lamp (200 - 400 nm)
Flow through Heater: Heated flowcell, ambient to 55 C, +/- 0.5 C accuracy.
Please inquire about our new PMT-FL-NIR option (below) for long wavelength emission sensitivities out to 860 nm
10 parts per trillion -
measured with Fluorescein @ 250 msec integration and internal tungsten lamp 27 parts per trillion - measured with 4 MU @ 250 msec integration time and internal mercury vapor lamp |
| |
| Please email
or phone FIAlab Instruments for additional product information. Email: fialab@flowinjection.com, Voice: 425-376-0450 or 1-800-963-1101, Fax: 425-376-0451 |
|